In aluminum window, door and façade systems, glass is chosen to meet the project's safety requirements, the way the opening is used, its dimensions, the required performance and the architectural appearance. On most projects, the consultant's specification makes the final call. The glass type alone is never a full specification: its make-up, thickness and fixing still have to be defined.
Tempered glass
Tempered glass is ordinary glass that has been heat-treated: heated, then cooled rapidly. This builds stresses into the glass that make it more resistant to impact and to temperature changes than untreated glass. When it does break, it shatters into small, blunt fragments rather than large, sharp shards, which reduces the risk of injury.
It comes with one practical constraint: it cannot be cut, drilled or edge-worked after tempering. Sizes, holes and notches have to be fixed before the glass is ordered. Tempered glass is common in doors, windows and other openings at risk of impact, and in façades where the specification calls for it.
Because it breaks up completely, tempered glass does not stay in place once broken. On its own, it may not be enough where the glass must remain in position after breakage.
Laminated glass
Laminated glass is two or more panes bonded together by a plastic interlayer. If it breaks, the fragments stay attached to the interlayer, and the pane tends to hold together in its frame instead of falling out.
That is why it is chosen where staying in place after breakage is a safety requirement, such as skylights and other overhead glazing, and wherever falling glass would put people below at risk. The interlayer also reduces sound transmission and cuts ultraviolet light; how much depends on the interlayer type and thickness.
The panes in laminated glass can themselves be tempered or untempered, depending on the specification. Lamination and tempering are different treatments, and one pane can combine both.
Insulated glass units
An insulated glass unit is two panes held apart and sealed around the edge, with the cavity between them filled with dry air or gas. The cavity reduces heat transfer through the glass compared with a single pane, so these units are used where the specification calls for better thermal insulation or control of solar heat gain.
Each pane in the unit can be tempered, laminated or coated, so one unit can meet safety and insulation requirements together. Its performance depends on several factors, including pane thickness, cavity width, any gas fill and the coating on one of the glass surfaces. Two units that are both called double glazed can therefore perform very differently.
How the right type is chosen
Glass is not chosen by name. It is chosen against a set of requirements reviewed together:
- Safety at the point of installation, such as the risk of impact, or glass above head height.
- Use and operation: fixed glazing, or glass in a sliding or hinged sash.
- Opening size and sash weight, which affect glass thickness and make-up as well as the choice of profile and hardware.
- The thermal, acoustic and solar-control requirements in the project specification.
- Appearance, including color, reflectivity and any treatment.
- The consultant's specification and the project's approvals, which have the final word.
Specifications often combine types, for example an insulated glass unit with a tempered outer pane and a laminated inner pane. These details are fixed in the specification and drawings before fabrication.
What the glass specification records
Once the type is chosen, the specification fixes the details that supply and fabrication depend on:
- The glass make-up and the thickness of each pane.
- The cavity, where insulated glass units are used.
- Any required color, treatment or coating.
- How the glass is fixed in the profile.
The system components that work with the glass, such as gaskets, sealants and fixings, are reviewed alongside it for compatibility with its make-up, thickness and operation.
Common issues in specifications
- "Double glazing" specified without the pane make-up, cavity width or coating, which makes it impossible to price or assess accurately.
- Tempered glass ordered before final dimensions are fixed, even though it cannot be altered after tempering.
- Tempered glass alone used in an overhead application where the glass must stay in place after breakage.
- A performance value requested for the glass alone, when the performance of an opening also depends on the frame.
Performance values come from documented data
Calling glass insulated or tempered does not establish a particular performance rating. Values such as thermal transmittance (U-Value) and solar heat gain coefficient (SHGC) come from the glass supplier's documented technical data for the exact make-up, and are reviewed together with data for the selected aluminum system, because the performance of an opening depends on the frame and the glass together.
At ENICAS, we coordinate glass supply and integrate it into our aluminum systems within the contract scope; the factory does not manufacture raw glass or temper it. We review performance requirements using data for the selected system and glass, and state a value only when a technical document supports it.